Ducted gas heating product range and specifications

 

TSS 6 star "Super-Six" ducted gas heater

braemar_thm6_starrating_f_web

 

 

 

 

 

  • Highest star rating available
  • Lowest running costs
  • Zone heating capable
  • Softair™ for greater comfort
  • Corrosion-resistant heat exchanger
    gold_supersix_badge_web
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
TSS623 1150 385 660 63 6.0 88 640 - 300 23.5 - Standard NG
TSS6X23 1150 385 660 63 6.0 88 - 695 300 23.5 - Standard NG

NG/ Propane">

 

THM 6 star Range

braemar_thm6_starrating_f_web

 

 

 

 

 

  • Highest star rating available
  • Zone heating capable
  • Softair™ for greater comfort
  • Corrosion-resistant heat exchanger

award_winner

 

Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
THM618 1150 385 660 58 6.0 70 500 - 300 17.9 - Standard NG
THM623 1150 385 660 61 6.0 88 640 - 300 22.5 - Standard NG
THM6X23 1150 385 660 61 6.0 88 - 755 350 22.5 - Standard NG
THM632 1165 510 660 73 6.0 122 935 - 350 31.2 - Standard NG
THM6X32 1165 510 660 73 6.0 122 - 1070 400 31.2 - Standard NG




THM 5 Star Non-condensing Range

braemar_thm5_starrating_f_web

  • Outstanding efficiency
  • Very economical to run
  • Zone heating capable
  • Softair™ for greater comfort
  • Corrosion-resistant heat exchanger
  • One third smaller than standard five star heaters
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
THM516 770 385 660 47 5.2 70 475 300 15.90 - Standard NG
THM520 770 385 660 50 5.2 88 630 300 20.0 - Standard NG
THM5X20 770 385 660 51 5.2 88 - 695 350 20.0 - Standard NG
THM530 880 510 660 70 5.2 122 960 350 27.8 - Standard NG
THM5X30 880 510 660 70 5.2 122 - 1050 400 27.8 - Standard NG




TH 5 Star Range

braemar_th5_starrating_f_web

  • Outstanding efficiency
  • Very economical to run
  • Zone heating capable
  • Softair™ for greater comfort
  • Corrosion-resistant heat exchanger
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
TH516 1150 385 660 58 5.6 60 500 - 300 16 - Standard NG/ Propane
TH523 1150 385 660 61 5.6 88 640 - 300 23 - Standard NG/ Propane
TH5X23 1150 385 660 61 5.6 88 - 755 350 23 - Standard NG/ Propane
TH532 1165 510 660 72 5.6 122 935 - 350 32 - Standard NG/ Propane
TH5X32 1165 510 660 72 5.6 122 - 1070 400 32 - Standard NG/ Propane




THMD 5 Star Range

thmd_5star_range_starrating_f

 

  • Replacement for other older heater products
  • Value for money
  • Easy to operate
  • Proven reliability
  • Softair™ for greater comfort

 

 

Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
THMD516 770 385 635 47 5.2 70 440 - N/A 15.9 - Standard NG
THMD520 770 385 635 50 5.2 88 490 - N/A 20.0 - Standard NG
THMD530 880 510 650 70 5.2 122 880 - N/A 27.8 - Standard NG




TH 4 Star Range

braemar_th4_starrating_f_web

  • High efficiency
  • Economical to run
  • Zone heating capable
  • Softair™ for greater comfort
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
TH415 770 385 660 47 4.7 60 475 - 300 14 - Standard NG/ Propane
TH420 770 385 660 50 4.7 80 630 - 300 18 - Standard NG/ Propane
TH4X20 770 385 660 51 4.7 80 - 695 350 18 - Standard NG/ Propane
TH425 770 385 660 54 4.7 100 755 350 23 - Standard NG/ Propane
TH4X25 770 385 660 54 4.7 100 810 350 23 - Standard NG/ Propane
TH430 880 510 660 70 4.7 122 960 - 350 28 - Standard NG/ Propane
TH4X30 880 510 660 70 4.7 122 - 1050 400 28 - Standard NG/ Propane
TH435 880 510 660 70 4.7 153 1050 400 35 - Standard NG/ Propane




TH 3 Star Range

braemar_th3_starrating_f_web_new

  • Value for money
  • Easy to operate
  • Proven reliability
  • Softair™ for greater comfort
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec.
ExtraAir
@100pa
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
TH315 770 385 660 47 3.7 60 475 - 300 14 Standard Optional NG/ Propane
TH320 770 385 660 50 3.7 80 630 - 300 18 Standard Optional NG/ Propane
TH3X20 770 385 660 51 3.7 80 - 695 350 18 Standard Optional NG/ Propane
TH325 770 385 660 54 3.7 100 755 - 350 23 Standard Optional NG/ Propane
TH3X25 770 385 660 54 3.7 100 - 810 350 23 Standard Optional NG/ Propane
TH330 880 510 660 70 3.7 122 960 - 350 28 Standard Optional NG/ Propane
TH3X30 880 510 660 70 3.7 122 - 1050 400 28 Standard Optional NG/ Propane




THD 3 Star Range

braemar_thd3_plenumbox_starrating_f_web_2

  • Specially designed to replace some popular old heater models
  • Advanced engineering, delivering easier and more efficient operation
  • Multi-level safety controls as standard
  • Electronic ignition and flame sensing
  • Home/Away setting (if used in conjunction with the optional Spectrolink Controller)
  • InShot Burner™
  • Softair™ for greater comfort
Model Dimensions Weight Rating Capacity Airflow Output Controller type
Length
(mm)
Width
(mm)
Height
(mm)
kg Stars MJ/hr
rating
Standard
litres/sec @100pa.
Supply
& Return
Duct
Diameter (mm)
kW Manual
Digital
Control
Spectrolink Gas Type
THD315 770 385 635 47 3.7 60 440 N/A - down discharge 14 Standard Optional NG
THD320 770 385 635 50 3.7 80 490 N/A - down discharge 18 Standard Optional NG
THD330 880 510 650 70 3.7 122 880 N/A - down discharge 28 Standard Optional NG

Bracket dimensions (to fit existing supply/return air plenum box) for THD315/THD320 – 770mm (W) x 395mm (D) and THD330 – 880mm (W) x 565mm (D)

 

View ducted gas heating features and benefits...

  • Climate Wizard